1.Genenal
Industrial use assembly thermocouple as measuring temperature sensor, usually are used with display instrument, recording instrument and electronic regulator. It can be directly measured various production process from 0 ℃ ~ 1800 ℃ within the scope of the liquid, steam and gas medium and solid surface temperatures. According to state regulations, our factory production standards conform to the IEC international standard degrees: platinum rhodium 30 - platinum rhodium 6, platinum rhodium 10 - platinum, nickel chrome - nickel silicon, nickel chrome - copper and nickel, copper - copper and nickel and iron - copper and nickel etc. thermocouples.
2. Type
B, S, K, E
3. Main technical parameter
Type
Code
Degree
Range ℃
Tolerance △t℃
platinum rhodium 30 - platinum rhodium 6
WRR
B
600~1600
±1.5℃ or ±0.25%t
platinum rhodium 10 - platinum
WRP
S
0~1300
±1.5℃ or ±0.25%t
nickel chrome - nickel silicon
WRN
K
-40~1000
±2.5℃ or ±0.75%t
nickel chrome - copper and nickel
WRE
E
-40~800
±2.5℃ or ±0.75%t
Quality guarantee:
1. Temperature/RTD technical feature accords with separately JB/T5582-91(IEC1515-95),JB/T9238-99 and JB/T8622-97(IEC751-83)
2. Qualification rate 100%, finished products deliver for one check qualification rate≥95%
3. To perform contract 100%
4. Quality guaranteed . Once received customer complain,we'll afford a clearly answer within 24 hours or a special messenger will be send to the locale within 48 hours.We promise that serves won't stop until the customer satisfied.