 It is widely used for supervising and controlling return circuit of rated voltage 450/750V or lower for production under high temperature in the field of steel & iron, refinery, power plant, coking plant, aviation, metallurgy, machinery, petrochemical industry etc. It has good feature of high temperature resistance, flame resistance, radiation resistance, aging resistance, ozone resistance, water proof, freezing resistance and weather resistance.

Executive standard: enterprise standard

Type, description and main application occasion listed in the following table


Type

Description

Main application occasion

(ZR)-KGG

Control cable with Cu core, silicon rubber insulation and sheath

To be fixedly laid indoor, in cable furrow or pipe

(ZR)-KGGP

Control cable with Cu core, silicon rubber insulation and sheath, braided shielding

Fixedly laid indoor, in cable furrow or pipe with demand on shielding

(ZR)-KGGP2

Control cable with Cu core, silicon rubber insulation and sheath, copper tape shielding

Fixedly laid indoor, in cable furrow or pipe with demand on shielding

(ZR)-KGGR

Control soft cable with Cu core, silicon rubber insulation and sheath

To be laid indoor or in the environment with demand on softness and mobility

(ZR)-KGGRP

Control soft cable with Cu core, silicon rubber insulation and sheath, braiding shielding

To be laid indoor or in the environment with demand on softness and shielding

Cable structure as follows


Type

Rated voltage

Nominal cross section area of conductor

0.5

0.75

1.0

1.5

2.5

4

6

10

Core number

KGG, KGGP, KGGP2

450/750

2~61

2~14

2~10

KGGR, KGGRP

4~61

4~48

2~14

Technical Parameter

    • Insulated resistance of finished cable insulated conductor will be no less than 50M under the condition that cable length is 1km and temperature is 20℃
    • Finished cable shall bear AC voltage test of 3000V under power frequency for 5 minutes without puncture of insulation

Related Products :
Self-thermal Control Heating Cable
Self-thermal Control Heating Cable
High-temperature resistant control cable with fluoroplastics insulation
High-temperature resistant control cable with fluoroplastics insulation
Control Cable with Low Smoke, Low Halogen and Flame Retardant
Control Cable with Low Smoke, Low Halogen and Flame Retardant
Silicon Rubber (flame retardant) Flat Power Cable
Silicon Rubber (flame retardant) Flat Power Cable
High Temperature Resistance (Flame Resistance) Power Cable
High Temperature Resistance (Flame Resistance) Power Cable
Vessel Power Cable with PVC Insulation and Sheath
Vessel Power Cable with PVC Insulation and Sheath
2kV Aluminum Photovoltaic Wire
2kV Aluminum Photovoltaic Wire
HIGH VOLTAGE CABLES
HIGH VOLTAGE CABLES