AnHui Electric Group Shares Co.,Ltd.

AnHui Electric Group Shares Co.,Ltd.

进入中文版  中文版 进入英文版  ENGLISH
Contact Us

Tel: +86-550-7309278
Fax: +86-550-7309288
Mobile: +86-13905505237
E-mail: 13905505237@163.com
Add: No.128, Tiancha Road, Economic Zone, Tianchang, Anhui, P.R.China
QQ: 641289349
QQ: 641289349

Products > POWER CABLES > > PVC Insulation & Sheath Power Cable of 0.6/1 kV or Lower
Product name : PVC Insulation & Sheath Power Cable of 0.6/1 kV or Lower
 Enlarge Image                   Back
←[Previous Product]              [Next Product]→


Details:
 It is used to transmit and distribute power on the power line of A.C. rated voltage 0.6/1kV

Executive standard:
GB/T12706.1 (equal to the standard of IEC60502)

Working condition:

  1. Long-term working temperature allowed by cable conductor shall be no more than 70℃
  2. Max. temperature of cable conductor shall be no more than 160℃ during short circuit(the longest lasting time shall be no more than 5 seconds).
  3. Environment temperature for installation shall be no less than 0℃

Type, Description and Application occasion


Type

Description

Application occasion

Cu

Al

VV

VLV

Power cable with PVC insulation and sheath

To be laid indoors, in the tunnel, cable furrow or pipe. The cable can not bear mechanical force from outside

VV22

VLV22

Power cable with PVC insulation, PVC sheath and steel tape armored

To be laid underground, the cable can bear certain mechanical force, but it can not bear great pulling force

Production Scope


Type

Core number

Nominal cross section area

Cu

Al

VV
--
VV22

--
VLV
VLV22

1

1.5~500
2.5~500
10~500

VV
--
VV22

--
VLV
VLV22

2

1.5~185
2.5~185
4~185

VV
--
VV22

--
VLV
VLV22

3

1.5~300
2.5~300
4~300

VV
--
VV22

--
VLV
VLV22

4

2.5~300
2.5~300
4~300

VV
VV22

VLV
VLV22

3+1

4~300
4~300

Main technical parameter of cable:

    • Max. value of conductor DC resistance shall meet the requirement of conductor of category 2 stipulated in GB/T3956 standard at 20℃
    • For single core cable without shielding, voltage test of 3.5kV under power frequency is put on for 5 minutes between conductor and water when be immersed in the water for one hour. For multi-core cable, between each insulated conductor and other conductor, voltage test of 3.5kV under power frequency is put on for 5 minutes without puncture of insulation.

Related Products :
Quadruplex Conductor 600 V Secondary Type URD Cable
Quadruplex Conductor 600 V Secondary Type URD Cable
Control Cable with XLPE Insulation and PVC Sheath
Control Cable with XLPE Insulation and PVC Sheath
Triplex Conductor 600 V Secondary Type URD Cable
Triplex Conductor 600 V Secondary Type URD Cable
Mining Cable XLPE Insulation Flame Retardant 8.7/10kV or Lower
Mining Cable XLPE Insulation Flame Retardant 8.7/10kV or Lower
Intrinsic Safety Type Computer Shielding Cable
Intrinsic Safety Type Computer Shielding Cable